词语吧>英语词典>first harmonic翻译和用法

first harmonic

英 [fɜːst hɑːˈmɒnɪk]

美 [fɜːrst hɑːrˈmɑːnɪk]

一次谐波;基(谐)波

电力

英英释义

noun

双语例句

  • Secondly, the principles of the LLC half-bridge resonant converter are presented and the performance of LLC resonant converter is analyzed using FHA ( First Harmonic Approximation) method in detail.
    其次介绍了LLC半桥谐振变换器的工作原理,并采用基波分析的方法对电路的特性进行详细分析。
  • After the nonlinear and absorption effect is taken into account in the applications where high power ultrasonic is involved, the first and second harmonic components of the sound field of stepped circular plate is analyzed, based on the KZK equation and quasi-linear condition.
    考虑到大功率超声应用中的非线性和吸收作用,本文从KZK方程和准线性条件出发,对于工作在共振频率下的这种阶梯圆盘,推导了它的一阶和二阶谐波声场计算方法。
  • Harmonic analysis of angle measuring error has been done through Fourier analysis theory. First harmonic, second harmonic and third harmonic have been compensated with the method of software. Finally, measuring results have satisfied the specific requirements.
    利用傅立叶分析理论对测角系统的误差进行谐波分析,补偿一、二、三次谐波误差,得到补偿公式,通过软件方式实现误差补偿,最后使得测量结果满足技术指标要求。
  • The first harmonic winding and harmonic winding no-load property curve are gained when field current is change.
    通过改变励磁电流的大小,得到了基波绕组和三次谐波绕组的空载特性曲线。
  • Phase splitting reactive power compensation of first harmonic in low voltage distribution network by computer controlled thyristor switch
    微机控制的晶闸管开关型低压配电网基波无功分相补偿
  • Through the method of curve fitting, the eccentric motion which is of the same frequency as the rotary speed is separated ( effectively) from the signals in the first harmonic component. Thus the rotational error of the spindle is determined correctly.
    应用数学方法曲线拟合法对测量信号中与转速同频的偏心运动和主轴误差运动中的一次误差运动进行了有效的识别分离,正确消除了偏心运动,实现了主轴误差的准确评定。
  • First Harmonic Saturated Absorption Frequency Stabilization of Lasers Using Sampling Integration Technique
    利用取样积分实现激光饱和吸收一次谐波稳频
  • The first harmonic measurement is achieved using analog filters, because the error is too large, real bad, harmonic measurement process is no longer the preferred method.
    最早的谐波测量是采用模拟滤波器实现的,由于误差太大,实时性太差,谐波测量过程中该方法已不再优先选用。
  • Because "DGB-2 Type Fast Track Dynamic Power Factor Compensation Device" has detecting circuit of reaching zero, the paper first analysis the harmonic detecting of starting to sample at reaching zero time and realize the upper harmonic detecting.
    因为DGB&2型快速跟踪动态功率因数补偿装置具有过零检测电路。论文首先对过零时刻开始采样的谐波检测进行分析,实现了过零时刻开始采样的谐波检测。
  • In this paper, the curve-fitting method is used for fitting the measuring signal distinguishes and retains the first harmonic component;
    本文应用曲线拟合法对测量信号进行拟合,识别并保留了一次误差运动,正确消除了测量球的偏心,从而得到包含一次误差运动在内完整的误差运动。